-40%
AEMC PEL 103 (2137.52) Power Energy Logger, 1-2-3-Phase, 3Sensors, LCD
$ 948.02
- Description
- Size Guide
Description
Subscribe to Our NewsletterAEMC PEL 103 (2137.52) Power and Energy Logger, Single, Dual and Three-Phase, with Three MA193-10-BK Sensors and LCD Display
Brand:
AEMC
Model No:
PEL 103
Ref No:
2137.52
Our Model No:
PEL103
Product Overview
Features
Simple to use, single, dual-split and three phase power and energy logger
LCD Display
Three MA193-10-BK Sensors included
Equipped with four powerful magnets for mounting the instrument on a metallic surface
1000V CAT III and 600V CAT IV
Measurement of RMS voltages and currents at 128 times per cycle and stored every second
Power Measurements: VA, W and var
Energy Measurements: VAh, Wh (source load) and varh (quadrant indication)
Updated features in DataView software for configuring real-time communication with a PC and report generation with pre-defined or user defined templates
USB, LAN, Ethernet and Bluetooth (Class 1 wireless communication, up to 300 ft. away)
Minimal programming required
Satisfies the recommendations of NEC Code 220.87
Can be configured from front panel, through Dataview control panel or free app
Power adapter allows the PEL 103 to be powered from a phase measurement input
Provides all the necessary functions for power and energy data logging for 50Hz, 60Hz, 400Hz and DC distribution systems
Automatic recognition of the connected current sensors/probes
Applications
Measure efficiency, find areas for potential savings
Track sub-billing occupants for energy costs
Assign energy costs to departments or operations within a department
Track peak demand periods and find opportunities for surcharge reductions
Determine present capacity and circumvent unnecessary electrical expansion costs
Monitor stray voltages and neutral current
Verify the reliability and operation of electrical machinery
Improve response time to solve power related problems
Track energy availability and reliability of supply
Reduce field service time at sub-stations
Baseline studies for system upgrades in high-rise and office buildings
Remote configurations, monitoring and event loading
Description
The AEMC PEL 103 (2137.52) is a low cost, simple to use, one, two (split phase) and three phase power/energy data logger. This product is ideal for electricians, engineers and contractors doing work in the area of building and system monitoring and upgrades, as well as residential and overall energy audits. All vital energy data is easily measured, recorded, and analyzed. Reports can be generated with confidence with minimal configuration time and effort (Standard and Customizable Reports supplied).
The PEL103's design enables it to be installed inside a load center panel (including the current sensors) allowing the door to close on most panels. The PEL 103 offers all the essential functions for logging power/energy data from most electrical power networks in use today across the world (17 network set-ups provided). The PEL103 energy logger measures and records three voltage inputs and current inputs, Watts, VARS, VA and Energy (kWh and kVA). Power Factor (PF), Displacement Power Factor (DPF), Crest Factor, Frequency and THD are calculated and recorded as well. Individual harmonic % information from 1 to the 50th harmonic are recorded at the operator's choice. All variables are recorded and stored at a one second interval and on user selectable demand intervals from 1 to 60 minutes.
The included, comprehensive DataView software also provides the ability to view data from several hundred PEL units on a local network or over the internet providing the ability to evaluate energy usage on a department or facility basis anywhere in the world. Real-time data can be reviewed as well as downloading stored results for analysis and report generation.
Configuration of the PEL-103 (2137.52) takes place through the DataView software either locally or remotely. Most of the configured parameters are pre-set in the instrument keeping the user interface simple and straightforward and easy to complete in a few minutes. Current probes are automatically defined and calibrated when they are plugged into the unit. User selections include network type, demand interval, recording length, voltage and current ratios where necessary, recording duration (defined either by time and/or date) and communication method. Pass word protection can be initiated for Bluetooth and network communication to guard against unauthorized access and protection of data integrity.
The DataView software provides the ability to review power, harmonic and RMS data in real time and to download recorded sessions for more extensive analysis and report generation. One second trend and demand interval trend graphs and tabular listings can be displayed and printed out. Energy costs can be calculated. Source and load graphs can be plotted. Individual phase and the sum of all phases can be evaluated. Once on screen, the user has access to a variety of analytical tools to analyze individual data points or sections of the recorded data without the frustration with having to deal with layers of button pushing to get to the information you need.
Included Components
1 - Small Classic Tool Bag
3 - MiniFlex MA193-10-BK Sensors
1 - 5 ft USB Cable
4 - Black Test Leads and Alligator Clips
1 - Power Cord
12 - Color-coded ID Markers
1 - Safety Card
1 - Sensor Compliance Sheet
1 - 2GB SD-Card
1 - Quick start guide
1 - USB Stick with DataView software
1 - User manual
Terms & Conditions
Please note estimated delivery time above. Contact us for details or if you have a delivery requirement. We ask for your patience while striving to ensure your shipment arrives quickly and accurately.
Domestic Shipping
FREE Standard Shipping on items OVER and less than 30lbs to continental U.S. Add for AK, HI, or PR. Please contact us for shipping rates to any overseas US territories including: Northern Mariana Islands, Guam, Puerto Rico, U.S. Virgin Islands and American Samoa.
PO Boxes/APOs require USPS shipping and may therefore experience longer lead times
6.25% Sales Tax for shipping to MA
International Shipping
Due to international voltage requirements, please ask us prior to purchasing to confirm your product will operate correctly in your country.
Please contact us for shipping rates to any overseas U.S. territories.
International customers are responsible for all shipping charges, including any duties or taxes.