-40%
Fluke 1732/B Three-Phase Energy Logger with Fluke Connect (No Probes)
$ 1671.64
- Description
- Size Guide
Description
Subscribe to Our NewsletterFluke 1732/B Three-Phase Energy Logger with Fluke Connect Compatibility (No Probes)
Brand:
Fluke
Model No:
1732/B
Ref No:
4706566
Our Model No:
1732B
Product Overview
Features
Does not include flexible current probes
Automatically capture and log voltage, current, power, power factor, energy and associated values
Included Energy Analyze Plus software to download and analyze energy consumption with automated reporting
Power instrument directly from measured circuit
High safety rating: 600 V CAT IV/1000 V CAT III rated
More than 20 separate comprehensive logging sessions can be stored
All measured values are automatically logged and can also be reviewed during logging sessions
Bright, color, touch screen with full graphical display
Optimized user interface with the intelligent verification function indicates correct connections, reducing user uncertainty
Optional Fluke Connect wireless system compatibility (requires optional wireless USB adapter)
Fluke Connect Mobile App
AutoRecord measurements: Take measurements automatically and instantly save them to your phone; wirelessly save measurements to Fluke Cloud and add text or audio annotations
TrendIt graphs: Trend measurements from a single session in a time series graph
ShareLive video call: View live tool measurements, video and audio to collaborate in real time with your entire team, without leaving the field
Fluke Cloud storage: Securely store up to 5 GB of data securely, per user
Reports: Create reports with accurate and traceable maintenance data
Description
The Fluke 1732B Three-Phase Energy Logger with Fluke Connect Compatibility (No Probes) introduces a new simplicity to discovering sources of electrical energy waste. Discover when and where energy in your facility is being consumed, from the service entrance to individual circuits. Access and share data remotely with your team via the Fluke Connect app so that you can maintain safer working distances and make critical decisions in real-time, reducing the need for protective equipment, site visits and check-ins.
Profiling energy usage across your facility helps you identify opportunities for energy savings, and provides you with the data you need to act on them. The new Energy Analyze software package allows you to compare multiple data points over time to build a complete picture of energy usage, which is the first step to reduce the cost of your energy bill.
Load Studies
Discover how much energy individual pieces of equipment are consuming when they are operating at minimum and maximum capacity. Check the capacity of circuits prior to adding additional loads (various standards exist for this process; in the US the NEC 220-87 is the recommended standard). Load studies can also identify situations where you might be exceeding the allowable load on the circuit, or when an agreed peak demand applies from the utility. For convenience, some load studies simply measure current, which makes installing measuring equipment quick and easy. It is often recommended that load surveys be performed for 30 days, so that all typical load conditions are encountered during the test.
Energy Assessments
Quantify energy consumption before and after improvements to justify energy saving devices.
Energy Surveys
Users often ask where measurements should be taken for an energy survey; the answer is multiple points within the facility. Start at the main service feeders, then compare the power and the energy measured there, with the readings from the utility meter to ensure that you are receiving the correct charges. Then move downstream to the larger loads; these should be easy to identify by the current rating of the electrical panels downstream of the service entrances. Measuring at many points will allow a full picture of energy usage across the facility to emerge. The next question users typically ask, "How long should an energy survey last?" This, of course, depends on the facility, but it is recommended that you measure for a period of time that matches a typical facility activity period. If the facility operates over a five day work week, with down-time on the weekend, a seven day survey will most likely capture its typical conditions. If the facility operates at a constant level for 24 hours a day, 365 days a year, a single day could be reasonably representative, as long as you avoid scheduled maintenance. To capture a full picture of the facility's energy usage, it is not necessarily required to have measurements made simultaneously at every consumption point in the facility. To get a comprehensive picture, spot measurements can be made and then compared on a sliding timescale. For example, you could compare the service entrance results from a typical Tuesday between 6:00 am and 12:00 pm, with those of a larger load in the facility. Typically, there will be some correlation between these profiles.
Logging Related Analog Measurements
When conducting energy studies, it is useful to log related analog measurements such as temperature, voltage, current and/or pressure. These variables provide a better overall picture of operating conditions and allow you to correlate asset performance data with energy consumption. Correlating these variables provides more of the data that you need to make cost-saving performance adjustments.
Power and Energy Logging
When a piece of equipment is operated it instantaneously consumes a specific amount of power in watts (W) or kilowatts (kW). This power is accumulated over the operating time and expressed as energy consumed in kilowatt hours (kWh). Energy is what your electric utility charges for; there will be a standard charge from the utility per kilowatt hour. Utilities may have other additional charges, such as peak demand, which is the maximum power demand over a defined period of time (often 15 or 30 minutes).
There may also be power factor charges, which are based on the effects of the inductive or capacitive loads in the facility. Optimizing the peak demand and power factor often results in a lower monthly electricity bills.
Simplified Load Studies
For situations where it is either difficult or impractical to make a voltage connection, the "Simple Load Study" feature allows users to perform a simple load study by measuring current only. The user can enter the nominal expected voltage to create a simulated power study. For accurate power and energy studies, it is required to monitor both voltage and current, but this simplified method is useful in certain circumstances.
Easy to Use
An innovative tangle-free flat voltage lead makes connections simple and reliable; the instrument's intelligent 'Verify Connection' feature automatically checks to make sure the instrument is connected correctly and can digitally correct common connection issues without having to disconnect measurement leads.
The detachable power supply can be conveniently and safely powered directly from the measured circuit. No more searching for power outlets, or having to run multiple extension cords to the logging location.
Analysis and Reporting
Capturing logged data is just one part of the task. Once you have the data, you need to create useful information and reports that can be easily shared and understood by your organization or customers. Fluke Energy Analyze Plus software makes that task as simple as possible. With powerful analysis tools and the ability to create customized reports in minutes, you will be able to communicate your findings and quickly solve problems so you can optimize system reliability and savings.
Fluke Connect: See it. Save it. Share it. All the facts, Right in the Field
Fluke Connect with ShareLive video call lets you stay in contact with your entire team without leaving the field. The Fluke Connect mobile app is available for Android and iOS and works with over 20 different Fluke products. Make the best decisions faster than ever before by viewing all temperature, mechanical, electrical and vibration measurements for each equipment asset in one place. Get started saving time and money by increasing your productivity.
Included Components
1 - Power Supply
1 - Voltage Test Lead Set
4 - Alligator Clips
1 - Soft Carrying Case
1 - Energy Analyze Plus Software (Thumb Drive)
1 - Line Cords
1 - Color Coding Set
1 - User Manual/Documentation (Thumb Drive)
Terms & Conditions
Please note estimated delivery time above. Contact us for details or if you have a delivery requirement. We ask for your patience while striving to ensure your shipment arrives quickly and accurately.
Domestic Shipping
FREE Standard Shipping on items OVER and less than 30lbs to continental U.S. Add for AK, HI, or PR. Please contact us for shipping rates to any overseas US territories including: Northern Mariana Islands, Guam, Puerto Rico, U.S. Virgin Islands and American Samoa.
PO Boxes/APOs require USPS shipping and may therefore experience longer lead times
6.25% Sales Tax for shipping to MA
International Shipping
Due to international voltage requirements, please ask us prior to purchasing to confirm your product will operate correctly in your country.
Please contact us for shipping rates to any overseas U.S. territories.
International customers are responsible for all shipping charges, including any duties or taxes.